PelviTone – The highest quality pelvic floor training device on the physiotherapy / rehabilitation market. Trusted by hundreds of therapist across Canada for over 15 years!
- Dual channel PelviTone device has all the features of Continence device, plus:
- Advanced multi-phase programmes where treatment is split into time phases with different stimulation parameters;
- Stronger symmetrical stimulation with the reduced Pulse Width : 50 – 330
- Three Custom programmes plus 11 Preset Continence programmes.
- Lock mode function to measure the home compliance (mA and time used)
What is included?
- Pelvitone electrical stimulation unit
- 9V Battery
- 2 lead wires ( connects electrodes to unit)
- User manual
- Soft storage case
- Prob are Not included
- Dual channel: individually isolated circuits.
- Amplitude: 0-90 mA into 500 Ohm load; actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 86 mA, at 1500 Ohms load the maximum will be limited to 65 mA.
- Type: Constant current, maximum output voltage 180 Volts +10 / -30 Volts
- Waveform: Symmetrical, rectangular bi-phasic with zero DC current.
- Selectable pulse width: 50 μS – 330 μS [2% accuracy].
- Pulse Rate selection: in the continuous mode 2 – 100 Hz [2% accuracy].
- Time duration of the treatment selectable: 1 minute to 90 minutes.
- Low Battery Indicator: If the battery goes below 6.9 volts +/- 0.2 volts the battery symbol will flash on/off once every second.
- Open Electrode Detect: If an open circuit is detected at the output of channel A or B the output current will be reset at zero.
- Ramp up time 0.1 – 9.9 seconds.
- If the battery voltage is below 6.6 (+/- 0.2) volts the unit will not turn on.
Physical dimensions: 134 x 69 x 29.7 mm.
Weight: 0.18 KG with battery.
Environmental Conditions for use:
+5 to +40 degrees Centigrade. 0-90% Humidity.
Environmental conditions for storage & transport:
-25 to +70 degrees Centigrade. 0-90% Humidity.
Programs on the Pelvitone®
Programme: P01 Pelvic Floor Pain 3Hz, 150uS, 1 sec ramp, Work continuous, 20 min
Programme: P02 Urge Incontinence 10Hz, 250Us, 1 sec ramp, WORK 5 sec REST 5 sec, 20 min
Programme: P03 Stress Incontinence 1 40Hz, 200uS, 1 sec ramp, WORK 6 sec REST 15 sec, 20min
Programme: P04 Stress Incontinence 2 30Hz, 200uS, 0.8 ramp, WORK 5 sec REST 8 sec, 20 min
Programme: P05 Frequency / Urge 1 10 Hz, 200uS, 1 sec ramp, WORK 5 sec REST 5 sec, 20min
Programme: P06 Frequency / Urge 2 10Hz, 200uS, 1 sec ramp, WORK Continuous, 15min
Programme: P07 Frequency / Urge 3 10Hz, 220uS, WORK continuous, 20min
Programme: P08 Lack of Sensitivity 3-40Hz sequentially 25 min
Programme: P09 Pelvic Floor Work Out 10-30Hz sequentially 45min
Programme: P10 Building up Endurance 20Hz, 250uS, 0.8 ramp, WORK 5 sec REST 5 sec, 20min
Programme: P11 Relaxing the Pelvic Muscles 2Hz, 220uS, 1.2sec ramp, WORK 6 sec REST 10 sec, 20 min
PC 1,2 or 3 : Customisable programs Choose from the following parameters - set your own program: 2-100Hz, 50-330uS, 1-99 min , work/rest 2-99 sec OR continuous can be used, 0.1 -9.9 ramp
-
Shipping Explained